User Tools

Site Tools


teknihall

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
teknihall [2015/11/27 21:09]
127.0.0.1 external edit
teknihall [2016/12/03 09:11] (current)
ckreuzberger [Protocol] Temperature Readings
Line 118: Line 118:
  
   * The ''​ID''​ is defined as a binary number ​   * The ''​ID''​ is defined as a binary number ​
-  * The ''​Temperature''​ is defined as a binary number and represents ​the temperature+  * The ''​Temperature''​ is defined as a binary number ​similar to the two complement, representing 3 digits, whereas the last digit is the digit after the comma. For instance ''​11 1111 1111''​ represents -0.1 °C and ''​00 0000 00'' ​represents ​0.0 °C. 
   * The ''​Humidity''​ is defined as a binary number and represents the humidity   * The ''​Humidity''​ is defined as a binary number and represents the humidity
  
-This protocol was created for pilight with the help of this thread+ 
-http://​forum.pilight.org/​Thread-Connect-digital-weather-sensor+Regarding the temperature,​ here are some example readings: 
 +<​code>​ 
 +-19.7 °C = 11 0011 1011 (0827) 
 +-15.0 °C = 11 0110 1010 (0874) // spec minimum 
 +-00.5 °C = 11 1111 1011 (1019) 
 +-00.1 °C = 11 1111 1111 (1023) 
 +-00.0 °C = 00 0000 0000 (0000) 
 ++01.8 °C = 00 0001 0010 (0018) 
 ++60.0 °C = 10 0101 1000 (0600) // spec maximum 
 ++69.6 °C = 10 1011 1000 (0696) 
 +</​code>​ 
 + 
 +This protocol was created for pilight with the help of these two threads
 + 
 +  * http://​forum.pilight.org/​Thread-Connect-digital-weather-sensor 
 +  * https://​github.com/​pilight/​pilight/​pull/​221 
teknihall.1448658544.txt.gz · Last modified: 2016/12/03 09:11 (external edit)