User Tools

Site Tools


lm76_v5_0

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

lm76_v5_0 [2015/11/27 22:09] (current)
Line 1: Line 1:
 +**I2C-bus LM76**
 +
 +^Feature^Support^
 +|Sending|{{http://​wiki.pilight.org/​lib/​images/​notsupported.gif}}|
 +|Receiving|{{http://​wiki.pilight.org/​lib/​images/​supported.gif}}|
 +|Config|{{http://​wiki.pilight.org/​lib/​images/​supported.gif}}|
 +
 +==== Supported Brands ====
 +^Brand^Protocol^
 +|lm76|lm76|
 +
 +==== Sender Arguments ====
 +
 +//None//
 +
 +==== Config ====
 +<​code>​
 +        "​living":​ {
 +                "​name":​ "​Living",​
 +                "​temperature":​ {
 + ​ "​name":​ "​Temperature",​
 + "​protocol":​ [ "​lm76"​ ],
 + "​id":​ [{
 +       ​  ​  "​id":​ "​0x4b"​
 + }],
 + "​temperature":​ 172
 +                }
 +        }
 +</​code>​
 +
 +==== Optional Settings ====
 +
 +^Setting^Default^Format^Description^
 +|device-decimals|1|number|How many decimals does the temperature information contain|
 +|gui-show-temperature|1|1 or 0|Don'​t display the temperature value|
 +|poll-interval|5|seconds|What should be the poll interval of the sensors|
 +|device-temperature-offset|0|number|Correct temperature value|
  
lm76_v5_0.txt ยท Last modified: 2015/11/27 22:09 (external edit)