User Tools

Site Tools


lm75_v6_0

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

lm75_v6_0 [2015/11/27 22:09] (current)
Line 1: Line 1:
 +**I2C-bus LM75**
  
 +^Feature^Support^
 +|Sending|{{http://​wiki.pilight.org/​lib/​images/​notsupported.gif}}|
 +|Receiving|{{http://​wiki.pilight.org/​lib/​images/​supported.gif}}|
 +|Config|{{http://​wiki.pilight.org/​lib/​images/​supported.gif}}|
 +
 +==== Supported Brands ====
 +^Brand^Protocol^
 +|lm75|lm75|
 +
 +==== Sender Arguments ====
 +
 +//None//
 +
 +==== Config ====
 +<​code>​
 +"​devices":​ {
 + "​temperature":​ {
 + ​ "​name":​ "​Temperature",​
 + "​protocol":​ [ "​lm75"​ ],
 + "​id":​ [{
 + "​id":​ "​0x49"​
 + }],
 + "​temperature":​ 17.2
 + }
 + }
 +},
 +"​gui":​ {
 + "​temperature":​ {
 + "​name":​ "​Temperature Sensor",​
 + "​group":​ [ "​Misc"​ ],
 + "​media":​ [ "​all"​ ]
 + }
 +}
 +</​code>​
 +
 +==== Optional Settings ====
 +
 +Device Settings
 +
 +^Setting^Default^Format^Description^
 +|poll-interval|5|seconds|What should be the poll interval of the sensors|
 +|temperature-offset|0|number|Correct temperature value|
 +
 +GUI Settings
 +
 +^Setting^Default^Format^Description^
 +|show-temperature|1|1 or 0|Don'​t display the temperature value|
lm75_v6_0.txt ยท Last modified: 2015/11/27 22:09 (external edit)