I2C-bus LM75

FeatureSupport
Sending
Receiving
Config

Supported Brands

BrandProtocol
I2Clm75

Sender Arguments

None

Config

        "living": {
                "name": "Living",
                "temperature": {
 			"name": "Temperature",
			"protocol": [ "lm75" ],
			"id": [{
       			   "id": "0x49"	
			}],
			"temperature": 172
                }
        }

Optional Settings

SettingDefaultFormatDescription
device-decimals1numberHow many decimals does the temperature information contain
gui-show-temperature11 or 0Don't display the temperature value
poll-interval5secondsWhat should be the poll interval of the sensors
device-temperature-offset0numberCorrect temperature value