User Tools

Site Tools


dht22_v7_0

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

dht22_v7_0 [2015/03/28 12:15]
pilino1234 created page for new nightly config options
dht22_v7_0 [2015/11/27 21:09]
Line 1: Line 1:
-**1-Wire dht22** 
  
-^Feature^Support^ 
-|Sending|{{http://​wiki.pilight.org/​lib/​images/​notsupported.gif}}| 
-|Receiving|{{http://​wiki.pilight.org/​lib/​images/​supported.gif}}| 
-|Config|{{http://​wiki.pilight.org/​lib/​images/​supported.gif}}| 
- 
-==== Supported Brands ==== 
-^Brand^Protocol^ 
-|1-Wire dht22|dht22| 
-|1-Wire am2302|dht22| 
- 
-==== Sender Arguments ==== 
- 
-//None// 
- 
-==== Config ==== 
-<​code>​ 
-"​devices":​ { 
- "​temperature":​ { 
- "​protocol":​ [ "​dht22"​ ], 
- "​id":​ [{ 
- "​gpio":​ 7 
- }], 
- "​humidity":​ 5.2, 
- "​temperature":​ 1.7, 
- "​poll-interval":​ 5 
- } 
-}, 
-"​gui":​ { 
- "​temperature":​ { 
- "​name":​ "​Temperature Sensor",​ 
- "​group":​ [ "​Misc"​ ], 
- "​media":​ [ "​all"​ ] 
- } 
-} 
-</​code>​ 
- 
-==== Optional Settings ==== 
- 
-Device Settings 
- 
-^Setting^Default^Format^Description^ 
-|poll-interval|5|seconds|What should be the poll interval of the sensors| 
-|humidity-offset|0|number|Correct humidity value| 
-|temperature-offset|0|number|Correct temperature value| 
- 
-GUI Settings 
- 
-^Setting^Default^Format^Description^ 
-|temperature-decimals|2|number|How many decimals the GUIs should display for temperature| 
-|humidity-decimals|2|number|How many decimals the GUIs should display for humidity| 
-|show-humidity|1|1 or 0|Don'​t display the humidity value| 
-|show-temperature|1|1 or 0|Don'​t display the temperature value| 
dht22_v7_0.txt ยท Last modified: 2015/11/27 21:09 (external edit)