 +**1-Wire dht11**
  
 +^Feature^Support^
 +|Sending|{{http://​wiki.pilight.org/​lib/​images/​notsupported.gif}}|
 +|Receiving|{{http://​wiki.pilight.org/​lib/​images/​supported.gif}}|
 +|Config|{{http://​wiki.pilight.org/​lib/​images/​supported.gif}}|
 +
 +==== Supported Brands ====
 +^Brand^Protocol^
 +|1-Wire dht11|dht11|
 +
 +==== Sender Arguments ====
 +
 +//None//
 +
 +==== Config ====
 +<​code>​
 +        "​living":​ {
 +                "​name":​ "​Living",​
 +                "​temperature":​ {
 + ​ "​name":​ "​Temperature",​
 + "​protocol":​ [ "​dht11"​ ],
 + "​id":​ [{
 +    "​gpio":​ 7
 + }],
 + "​humidity":​ 52,
 + "​temperature":​ 17,
 + "​poll-interval":​ 5
 +                }
 +        }
 +</​code>​
 +
 +==== Optional Settings ====
 +
 +^Setting^Default^Format^Description^
 +|device-decimals|1|number|How many decimals does the temperature information contain|
 +|gui-show-humidity|1|1 or 0|Don'​t display the humidity value|
 +|gui-show-temperature|1|1 or 0|Don'​t display the temperature value|
 +|poll-interval|5|seconds|What should be the poll interval of the sensors|
 +|device-humidity-offset|0|number|Correct humidity value|
 +|device-temperature-offset|0|number|Correct temperature value|